Product Prices Listed On Our Website Are Exclusive Of VAT

TECNI 4mm Cable Balustrade System with Length & Terminal Options

Cable Balustrade Infill Options for installing into metal, wood or masonry, our balustrade kits provide all the necessary parts for one balustrade run (one single cable length):

  • 1 x Left hand M6 Balustrade tension fitting (either straight or angle type).
  • 1 x Right hand M6 Balustrade tension fitting (either straight or angle type).
  • 4mm Stainless Steel Cable to the length selected. 
  • 1 x set of TECNI Cable cutters (1 set per order).

PLEASE ADD 1 x SET OF CABLE CUTTERS TO THE CART & USE CODE FREECUTTER AT CHECKOUT
Go to 4mm Cable Cutter

Angled and Straight runs available to suit your requirements.

Please note that cable will be in one length and will need to be cut to length upon installation (1 set of cable cutters supplied with each order).

Our A4 AISI 316 Marine Grade Stainless Steel TECNI Standard balustrade fittings are perfect for straight or angled cable runs through wood or metal posts. Supplied with sufficient 4mm 7x7 Stainless Steel Marine Grade Cable it looks great on decking, verandas & at the poolside.

£21.26 to £40.96
Product Code: 4MM-BALUSTRADE-INTO

Straight/Angled Cable

Balustrade End Fitting 1

Balustrade End Fitting 2

Please select options before adding to cart

Applications & Advice

Find out more information about all our balustrade systems -

TECNI Cable Balustrade product guide

Technical Info

Download the Datasheet Here

    • A top rail, capable of withstanding a compressive load, should be fitted to help absorb the considerable force exerted by the cables on the end posts. Without one the posts are likely to fall in and the cable to go slack.

 

    • When drilling your posts and anchor points, the following sizes apply for the M6 system:
      • Intermediate post clearance holes: wire size +1mm.
      • Wooden anchor points - Pilot hole of 4mm
      • Steel anchor points. Drill 5mm hole and Tap M6
      • If tapping into metal posts, ensure the tapping tool is straight in all planes. The angle at which the 5mm holes are drilled into the posts is critical. Be sure that the measurement point and position of the holes are correct.

 

    • For the best look, when screwing the studs into the posts ensure the depth of the stud and the amount of visible thread is the same for each stud all the way down the post.

 

  • For correct tensioning using 75mm (3 in) spacings the cable should not deflect to more than 100mm (4 in). If you have the means to test it, tension the cables to 102kgf (225lbs) per cable


Note: You should always check with your local planning office to confirm that horizontal wires will be allowed



Video

Downloads

Download the Datasheet Here

  • A top rail, capable of withstanding a compressive load, should be fitted to help absorb the considerable force exerted by the cables on the end posts. Without one the posts are likely to fall in and the cable to go slack.

 

  • When drilling your posts and anchor points, the following sizes apply for the M6 system:
    • Intermediate post clearance holes: wire size +1mm.
    • Wooden anchor points - Pilot hole of 4mm
    • Steel anchor points. Drill 5mm hole and Tap M6
    • If tapping into metal posts, ensure the tapping tool is straight in all planes. The angle at which the 5mm holes are drilled into the posts is critical. Be sure that the measurement point and position of the holes are correct.

 

  • For the best look, when screwing the studs into the posts ensure the depth of the stud and the amount of visible thread is the same for each stud all the way down the post.

 

  • For correct tensioning using 75mm (3 in) spacings the cable should not deflect to more than 100mm (4 in). If you have the means to test it, tension the cables to 102kgf (225lbs) per cable


Note: You should always check with your local planning office to confirm that horizontal wires will be allowed